Reference: 29001
Allows a device to be activated for a given time (programmable from 0 to 6 min, or from 0 to 60 sec.). Activation can be done automatically or by means of a specific push button on the telephone or monitor.
The timer has the following connections and controls: - PDT relay to activate the external device (C, No, Nc). - Potentiometers to adjust the activation time: Minute adjusted potentiometer (P1) and Second adjusted potentiometer (P2). - Timed Activation Button Connection (S,-): activates the timer relay during the programmed time. - Button connection for Reset (R,-); Allows the timer to be deactivated before the programmed time has elapsed. - Direct Activation Button Connection (Ab ,-): activates the timer relay when the button connected here is pressed. - Connection for call activation (I1, I2): allows the calling wire and the negative from the outdoor panel be connected (4+N systems) and activate the time when making a call.
- Power supply: 9~14 Vac ;11~18 Vdc - Consumption: With 12 Vdc power supply: 20 mA standby, 50 mA active. With 12 Vac power supply: 50 mA standby, 110 mA active. - Maximum output values: Power (resistive load): 1250VA or 150W Voltage (resistive load): 125 Vdc, 380 Vac. - Maximum Temperature: 0~+65ºC - Timing: P1: between 0 and 6 minutes approximately. P2: between 1 and 60 seconds approximately. - Call Activation: Electronic Call: 4Vpp~18Vpp. Backup Call: 4Vac~12Vac.
Technology: GENERICA
Peso: 0,073 kg
Measures of the packed product: 9x6,5x2,5 cm
EAN 13: 8424299290010
Technisch informatieblad