DUOX RELAY MODULE

DUOX RELAY MODULE

Reference: 3257

The DUOX Relay allows for dry contacts in DUOX systems, with various operating and activation modes to be configured:
- Relay activation using commands generated from the residential terminals, entry...

Description

The DUOX Relay allows for dry contacts in DUOX systems, with various operating and activation modes to be configured:
- Relay activation using commands generated from the residential terminals, entry panels or guard units.
- External activation using buttons, additional external switches, etc.
The DUOX relay can be installed in any part of the duox bus. You can install one or several relays: by apartment, block or installation.

DUOX System:
this is the first completely digital system in two-wire non-polarized technology. This is the most technologically advanced system in the world, allowing fast installation with just two wires. The most highly simplified and advanced installation system on the market. It maximizes intercom system capacities thanks to digital audio and video transmission.

Duox offers maximum ease of installation, enabling transmission of all signals: power feed, audio, video and data with the highest capacities.

It permits management of
- From 1 to 999,999 apartments:
• Calls from pushbutton panel: 99.
• Calls from keypad panel:
- Sub-block: 99.
- Block: 9999.
- General entry: 999999.

- From 1 to 10 panels:
• Number of panels:
- General entry: 10.
- Block: 10.
- Sub-block: 10.

The maximum distance will depend on the installation topology and cable. See table of sections and distances for more details.

DUOX offers maximum versatility thanks to the stability and strength of signal transmission in this fully digital system which avoids possible feedback and interference in the installation.

The DUOX amplifier includes a voice synthesizer. Operating the lock release issues a message: “door open, close after entry”.

Up to three terminals (telephones/monitors) can be installed in each apartment.

Apartment terminals require simple programming. This programming assigns a call code to each terminal.

Communication is private.

Cables:
Any type of cable may be selected: parallel, twisted pair and UTP CAT5 in new installations; even existing cables in replacement work can be used (5 wires, 2-wire bell or old 4+N wire).
Non-polarized 2-wire.
Please check the sections-distances-terminals-power supply table.

Technical Specifications

Power supply: 18 Vdc (non-polarised, via the BUS INPUT or BUS OUTPUT).
- Consumption:
* On standby: 28 mA.
* Maximum: 64 mA (without power in the output and without the programmer connected).
- Operating temperature: [0, 40ºC].
- IP Address: 20.
- (+12V): Auxiliary voltage output 12Vdc (300 mA max).
- Dry contact relay:
- C: common.
- NC: normally Closed.
- NO: normally Open.
* Maximum current 3A.
* Maximum voltage 300VAC or 60VDC.

Power: 18 VDC

Weight: 0,365543 kg

Size of product when packed: 7,5x23x17,8 cm

EAN 13: 8,4243E+12