JEDNOSTKA CENTRALNA MDS

JEDNOSTKA CENTRALNA MDS

Referencja: 2405

The MDS central unit is the controller for MDS Digital audio/video door entry and access control systems.

Lets you integrate the following functions:
- Video door entry system with electronic d...

Opis

The MDS central unit is the controller for MDS Digital audio/video door entry and access control systems.

Lets you integrate the following functions:
- Video door entry system with electronic directory and multiple guard units.
- Access control for residents.
- Lift control for residents and visitors.
- Automated services: switching on/off lighting, irrigation, purification, etc.
- Technical alarms in the community and home.
- Intercommunication between guard units and elevators, garages, stair landings.


Being able to integrate all these functions in the same equipment mean a great saving by sharing resources and infrastructures (wiring, controllers) and simplicity of management: one-person maintenance and management.

Communication with all devices is by means of communication buses that enormously facilitate installation of the product.

Each central unit comes provided with a PC configuration and administration software (Wincom+) with the following functions:
- User authorizations and cancellations: electronic directory, access control.
- Access restrictions configuration.
- Incidents record.
- Installation test.

Łatwa instalacja wewnątrz skrzynki elektrycznej na szynie DIN 10 lub możliwość przykręcenia bezpośrednio do ściany.

System MDS Digital: Cyfrowy system domofonowy i wideodomofonowy do zarządzania budynkami i kompleksami mieszkalnymi dowolnej wielkości, który pozwala zintegrować wszystkie usługi dla lokatorów i wyróżnia się uproszczoną instalacją magistrali:
- Systemy domofonowe i wideodomofonowe
- Komunikacja pomiędzy wejściami.
- Kontrola dostępu
- Centralne i zautomatyzowane zabezpieczenia

Wymagane zastosowanie jednostek centralnych do zarządzania instalacją (jedna jednostka centralna może obsługiwać 9999 lokali i 32 wejścia / portiernie. Możliwość podłączenia maks. 63 jednostek centralnych). Możliwość obsługi wejść głównych lub klatek wewnętrznych.
Systemy MDS wymagają użycia dekoderów na poszczególnych piętrach w celu połączenia lokali z magistralą instalacyjną. Dekodery pełnią rolą izolatorów. Komunikacja pomiędzy lokalami i panelem ma charakter prywatny.

Okablowanie:
- Audio: magistrala 6-żyłowa.
- Wideo: magistrala audio + przewód koncentryczny (wideo) + 2 przewody zasilające.
Maksymalna odległość instalacyjna zależy od przekroju użytego przewodu (zob. dokumentacja techniczna).

Centralized MDS Access Control System. Composed of one part hardware: MDS central units, readers, decoders, etc. and one part software that lets you configure and manage the installation.

Restricts access to certain private zones of a facility (office, warehouse, factory, sports area) to those persons not in possession of a authorized credential or identification.

Enables complete management of an installation with several doors and advanced access control functions: restrictions by user groups, both spatial (areas) and temporal (schedules), anti-passback function, capacity limitation, greater user capacity, activation of devices from the reader, recording of incidents for consultation later, control or security centre.

In contrast with other systems, MDS access control lets you integrate other complementary functions with no need for additional controllers:
- Intercommunication. For those accesses where we have to allow access to other people from outside the facility. By pressing a button we contact the control centre and access is permitted from there.
- Lifts. Access to certain floors may be restricted depending on the identifier.
- Technical or intruder alarms. Each entrance and exit can be programmed with a detection and action time.- Automation. Weekly programmer which can schedule up to 32 daily activations of relays and arming of sensors, individually or in groups.

The user information and associated restrictions are stored in a Central Unit that takes the decisions to allow or deny access.

In facilities that exceed these specifications (more readers or users) up to 63 central units can be grouped together.

Reader wiring: 2 wires + screened twisted pair
Intercommunication wiring. 4 wires + screened twisted pair.

Specyfikacje Techniczne

Power supply: 12 Vdc
Consumption: 150 mA
Operating temperature: 10 to 60 ºC
Programming software: Wincomplus (Cd included with central unit)

* Audio and Video Door Entry System (MDS Digital)
- Capacity for up to 32 accesses, between audio and/or video panels and guard units, (using switcher modules Ref. 2379) per central unit. If there are several central units (more than one) interconnected via FXL network, the capacity per central unit is 31 accesses.
- Capacity for up to 10 Central Guard Units per central unit (each Central Guard Unit is equivalent to one access).
- Handles up to 9.999 homes.
- Residents electronic directory: name, flat, door, etc. … with capacity for up to 1022 users.
- User personal codes.
- Up to 999 audio panels for intercommunication of 1 or 2 pushbuttons by means of panel decoders.
- Possibility of connection between central units (up to a total of 63) via FXL Network.
- Incidents record. Records are stored in the central guard unit’s internal memory (Off-line mode) and in the PC (On-line mode).
- Possibility of management by PC and remote management by IP or modem (by means of additional modules).

* Access Control System (Digital MDS Controller)
It has all the features of the MDS DIGITAL AUDIO and VIDEO DOOR ENTRY system and specific access control functions:
- 32 accesses per Central Unit: keypad accesses, proximity card, RF, etc. If audio accesses are not used, the switcher modules are not necessary. If there are several central units (more than one) interconnected via FXL network, the capacity per central unit is 31 accesses.
- Up to 63 Central Units connected to each other.
- Up to 1022 users.
- Up to 999 sensors (by means of sensor decoders) per central unit.
- Up to 999 relays (by means of relay decoders) per central unit.
- PC software for programming and management of the installation (local and remote).
- Technical alarms and automation (by means of sensor decoders and relays).
- Intercommunication: Up to 999 audio panels for intercommunication of 1 or 2 pushbuttons by means of panel decoders and Central Guard Unit.

Wymiary szyny DIN 10: 175 mm x 90 mm x 60 mm

Zasilanie:
- Audio: 12 V DC
- Wideo: 18 V DC

Power supply: 12 Vdc

Waga: 0,677413 kg

Rozmiary opakowanego produktu: 7,5x23x17,8 cm

EAN 13: 8424299024059